General Considerations
• The cooling rate should be sufficient to control the flocculation and setlling of yeast to give the desired yeast count at rack.
The rate of cooling depends on:
• Flocculation characteristics of the yeast.
• Fermenter design, i.e. square or cylindroconical.
Range of Values
• Initial beer temperature is usually 19° - 22° C (66° - 72° F).
• The temperature of cooled beer is typically 12° - 14° C (54° - 57° F).
• Typical rates of temperature fall are 1° C (2° F) every 8 hours in squares, and 1° C (2° F) every two hours in cylindroconical vessels
• The 'Cleansing' period in squares is typically 2 - 3 days.
Operational Protocols
• The temperature of the beer should be measured every 4 - 6 hours and the flow rate of coolant adjusted accordingly.
• The flow of coolant is preferably automatically controlled
Measurement Protocols
• Temperatures should be measured as far away as practicable from the attemperators. |
|
| |